<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-18 01-38-41
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 75 kHz 16419 26,0674
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,6 dBr 5,53 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 75 kHz MIN: 11 kHz % above 76 kHz: 26,0674 Acquired: 2026.09.18 1.37.38 Total samples: 16419 Equivalent time: 0:13:40 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,1 dBr MIN: 4,6 dBr AVE: 5,53 dBr % above 12,2 dBr: 0,0 Last value: 5,9 dBr (2026.09.18 1.37.38) 01.24 01.26 01.28 01.30 01.32 01.34 01.36 0 2 4 6 Pm [dBr]